夜福利视频精品99热99|特aaa级在线播放|城市护士久久久老司机亚洲|在线国产无码av免费网页|另类av在线最新av|日韩a片无下载免费看|亚洲日韩在线免费观看视频|国产日韩精品无码去免费专区国产|欧美日韩se日韩黄色三级片|中国特级AAA级黄色毛片

Contact Us

What is the Cross Flow Fan principle ?

Date: 2016-5-24   Click: 1921 Times

"Cross Flow Fan", also known as through-flow fan, the 1892 French engineer Mortes (Mortier) first proposed multi-leaf impeller, long cylindrical shape, having a forward multi-wing blade. When the impeller rotates, air enters the open from the impeller cascade through the interior of the impeller, volute discharged from the other side of the cascade, forming working air flow. Air flow in the impeller flow situation is very complicated, non-steady gas flow velocity in the impeller there is a vortex, located near the center of the volute tongue. The existence of the vortex, the output of the impeller creates a circulating flow in the vortex, the air flow within the impeller line circular arc. Therefore, the impeller outer circumference of the flow rate at each point is inconsistent, closer to the vortex center, the greater the speed, the more close to the volute, the speed is smaller. Fan in the outlet air flow rate and pressure is not uniform, and thus the fan flow coefficient and pressure coefficient is an average value. Vortex position on the cross-flow fan performance is large, the vortex center close to the circumference of the volute tongue and close to the impeller, fan performance is better; from the center of the vortex vortex tongue far, the zone recycle stream is increased, reducing the efficiency of the fan, the flow is not increase the degree of stability.

Back to: Industry news

+86-0769-83660708

Home Product News Contact